Rinnai Tankless Error Code 79: What Water Detected Inside the Unit Means for East Cooper Homes

Writer: Christian Devlin
Christian Devlin
Sep 28
3 min read

If your Rinnai tankless flashes Code 79 in Mount Pleasant, Daniel Island, or somewhere else in East Cooper — stop and treat it seriously.

Code 79 means the heater detected water at the bottom of the cabinet. That is an internal leak, not a random display glitch. Rinnai shuts the unit down on purpose so dripping water does not keep soaking gas valves, wiring, and the control board.

I'm Christian with Avery & Sons Plumbing + Tankless. We see Code 79 around Charleston often enough that neighbors deserve a plain walkthrough — what it means, what you can safely check, and when to call.

What the unit is doing

Most modern Rinnais have a leak sensor near the base of the heater. When water pools there, the board throws Code 79 and locks out. Same idea as other hard stops: the heater would rather leave you without hot water than keep running with water, gas, and electricity mixed in one box.

This is different from a wet garage floor from a loose outdoor faucet, and different from Code 25 (condensate drain problem on condensing models). Code 25 is about acidic condensate not leaving the drain path. Code 79 means water showed up where it does not belong — inside the unit itself.

Common causes we see around here

Heat exchanger leak. Scale, freeze damage, or age can open a weep in the HEX. Around Charleston and East Cooper, hard water and skipped flushes are a big part of that story. A weeping exchanger can also foul flame sensing (we covered that under Code 72).

Fitting or connection leak. Inlet/outlet unions, pressure-relief piping, recirculation tees, or a loose joint inside the cabinet can drip onto the sensor. Outdoor and garage installs in Mount Pleasant and Daniel Island get condensation and corrosion that loosen things over time.

Condensate backup into the cabinet. On condensing units, a clogged condensate line or neutralizer can overflow. Sometimes that looks like Code 25 first; if enough water reaches the bottom sensor, you get Code 79.

Frozen or cracked lines after a cold snap. Lowcountry freezes are short, but a poorly insulated outdoor unit or a freeze-protection failure can crack a line. When it thaws, Code 79 is how you find out.

Safe checks you can do yourself

Keep it simple. If you smell gas, leave and call your gas utility — do not troubleshoot.

  1. Turn off the water supply to the heater. Rinnai's own guidance for Code 79 starts here. Closing the isolation valves (or the main if you do not have isolators) stops the drip from getting worse while you wait for help.

  2. Kill power at the breaker once water is shut off, if you can do that safely without standing in water.

  3. Look from outside — do not open the cover. Puddle under the unit? Rust trails? Wet insulation? Note what you see; photos help.

  4. Check obvious external sources. Washer drain, AC condensate, hose bib, or roof leak dripping onto the heater from above? Still have a pro clear Code 79 before you run the unit again.

  5. Do not keep resetting. Clearing the code without fixing the leak just invites more water into electronics.

Do not pull panels and start tightening fittings with gas and power still live. Internal leak diagnosis on a gas appliance is licensed work.

When to call a pro

Call the same day if Code 79 is on the display, if you see standing water under the heater, if the unit is in a finished space, or if anything smells like gas or burnt electronics.

A real service call will find the leak source (HEX, fitting, condensate path, or something else), dry and inspect the board and wiring, and tell you straight whether you are looking at a repair or a replacement. Around Charleston, Daniel Island, Mount Pleasant, and the rest of East Cooper, we see Code 79 most often from scale-damaged heat exchangers, loose unions after years of vibration, and condensate overflows nobody noticed until the sensor tripped.

Soft next step

If your Rinnai is throwing Code 79, shut the water to the unit and get eyes on it. Avery & Sons Plumbing + Tankless can help. Call (843) 305-5555 or visit averysplumbing.com. We're local, we work these heaters every week, and we'll tell you what it needs without the scare tactics.

Stay safe — Code 79 exists because water inside a gas heater is not a wait-and-see problem.

 
 
 