Rinnai Tankless Error Code 38: What an Exhaust Gas Temperature Sensor Fault Means for East Cooper Homes

Writer: Christian Devlin
Christian Devlin
Oct 16
3 min read

If your Rinnai tankless is flashing Code 38 in Charleston, Daniel Island, Mount Pleasant, or anywhere else in East Cooper, the heater is flagging a problem with its exhaust gas temperature sensor. That sensor sits in the exhaust path and tells the heater how hot the flue gas is running. If the heater can't get a reading it trusts, it won't keep running normally.

I'm Christian with Avery & Sons Plumbing + Tankless. Here's what Code 38 means, what you can safely check, and when it's time to call.

What Code 38 actually means

Code 38 points at the exhaust gas temperature sensor, which is a small thermistor. A thermistor changes its electrical resistance as it heats up or cools down, and the PC board reads that change as a temperature. Rinnai's troubleshooting for Code 38 applies to both SENSEI series and non-SENSEI series units.

This is a different code from Code 54, which we've written about before. Code 54 means the exhaust is actually running too hot. Code 38 is about the sensor itself, its wiring, or conditions around the heater that make its reading look wrong. The two can be related, which is why a good tech checks the whole picture and doesn't just swap the part.

Common causes

Rinnai's troubleshooting guide works through Code 38 in roughly this order:

  • Wiring problems. A loose, broken, or damaged connection in the sensor harness, either at the sensor or at the PC board.

  • A bad sensor. The tech pulls the sensor and checks its resistance with a meter. If the readings are off, the sensor is likely the problem.

  • Wrong gas type or a botched conversion. The heater has to match the gas it's hooked to (natural gas or propane, per the rating plate). If it was ever converted from one to the other, the conversion has to be done exactly the way Rinnai spells out for that model.

  • Clearance problems. Proper clearances have to be kept around the heater and the vent terminals.

  • Settings for the location. Parameter settings or dip switches have to match the installation. If they're wrong, the heater can misbehave.

  • Gas pressure. A qualified tech checks the low and high fire manifold gas pressures with a manometer.

  • Debris or blockage. The burner manifold, burner assembly, and the copper fins on the heat exchanger get inspected for buildup.

  • Venting. The vent has to be within Rinnai's clearance and length specs.

If all of that checks out and Code 38 still shows, the sensor gets replaced.

Safe checks you can do yourself

  1. Write down what you see. Note the code, when it showed up, and whether you've got any hot water at all.

  2. Try one reset. Turn the heater off at the controller, cut power at the breaker for about 30 seconds, then restore power and open a hot faucet. If Code 38 comes right back, leave it off and call.

  3. Look at the vent terminal from a safe distance. Make sure nothing is stacked against it, no shrubs have grown up around it, and nothing new has been built close to it. Don't touch the vent. It can be hot.

  4. Think about recent work. Was the heater ever converted to propane or natural gas, moved, or re-vented? Tell your tech. It narrows things down fast.

Please don't open the cabinet, pull the sensor, or change dip switches yourself. That's live power and gas, and Rinnai's own guide says those steps are for someone qualified to service gas systems.

When to call a pro

Call if Code 38 returns after one reset, if it comes and goes during the day, or if you've also seen Code 54. A proper visit should check the sensor wiring, test the sensor, confirm the gas type and pressures, look at clearances and venting, and inspect the burner and heat exchanger for buildup. Only then does it make sense to replace the sensor.

A local note

Around the Lowcountry, a lot of tankless units sit on exterior walls and in garages, and landscaping has a way of creeping in on vent terminals over a few summers. On Daniel Island and in Mount Pleasant we also see heaters that were added on or relocated during a remodel, so venting and clearances are worth a second look. And if you're out toward Awendaw or anywhere else running propane, make sure the heater was actually set up for it.

Soft next step

If your Rinnai is showing Code 38, try one clean power reset and check that the vent area is clear. If the code sticks, leave it off and get it looked at. Avery & Sons Plumbing + Tankless can help. Call (843) 305-5555 or visit averysplumbing.com. We're local, we work on these heaters all the time, and we'll tell you straight whether it's a connection, a setting, or the sensor.

 
 
 