Rinnai Tankless Error Code 32: What an Outgoing Water Temperature Sensor Fault Means for East Cooper Homes
If your Rinnai tankless stops heating right and the display shows Code 32 in Mount Pleasant, Daniel Island, or somewhere else in East Cooper — here's the short version.
Code 32 is an outgoing water temperature sensor fault. On Rinnai's list, that means the thermistor that watches the hot water leaving the heater isn't reading the way the control board expects. The unit protects itself. Bad temperature feedback is how you get scalds or a unit that won't fire when you need it.
I'm Christian with Avery & Sons Plumbing + Tankless. We work these units all over Charleston, and Code 32 shows up when the outlet sensor wiring is damaged or loose, the sensor itself has failed open or shorted, scale has built up on the probe, or — less often — the harness back to the board is the weak link.
What the unit is doing
Your Rinnai doesn't guess water temperature. A small thermistor near the hot outlet constantly reports what left the heat exchanger. The board uses that signal to modulate the burner and keep the set temperature steady. When the reading goes out of range — wiring open, shorted, scaled over, or a dead sensor — you get Code 32.
Rinnai's remedy language is straightforward: check sensor wiring for damage; measure resistance of the sensor; clean the sensor of scale build-up; replace the sensor. That sequence matters. Scale and a chewed harness look like a "bad sensor" until somebody actually checks.
If you're comparing codes: we already covered Code 10, Code 11, Code 12, Code 14, Code 16, Code 03, Code LC, Code 25, and Code 61 for East Cooper homes. Code 32 is about the outgoing (hot outlet) temperature sensor — not ignition, combustion fan, condensate, Bath Fill, or the separate heat-exchanger outgoing sensor that throws Code 33.
Common causes we see around here
Scale on the sensor. Hard water around Charleston, Mount Pleasant, and the rest of East Cooper leaves mineral film on probes. A coated thermistor reads wrong long before the heat exchanger itself is totally plugged. Code LC is the big scale warning; Code 32 can be the smaller cousin when the outlet probe is the part that fouled first.
Damaged or loose wiring. The harness from the outlet thermistor back to the PC board has to stay clean and tight. Vibration, cabinet work, rodents, and salt-air corrosion near the coast all show up here.
Failed thermistor. Sensors open (infinite resistance) or short. Rinnai's path ends at replacing the sensor when resistance is out of spec after wiring and cleaning checks.
Wrong diagnosis vs Code 33. Code 33 is the heat exchanger outgoing temperature sensor. Same style of fix — wiring, resistance, clean, replace — but a different part. Don't swap the outlet probe for the HX sensor just because both are "temp codes."
Safe checks you can do yourself
Keep it simple. If you smell gas, leave the area and call your gas utility first — don't troubleshoot.
1. Confirm the display. Write down Code 32 exactly. Note whether you get lukewarm water, no fire at all, or wild temperature swings before the code locks in. That detail helps a tech later.
2. Power-cycle once. Turn the unit off, wait about 30 seconds, turn it back on. If Code 32 was a one-time glitch, it may stay gone. If it comes right back, something still needs service.
3. Check the inlet filter if you're comfortable doing it. A clogged cold-water inlet screen can make flow and temperature behave oddly. That's not the same as replacing the outlet thermistor, but it's a safe homeowner step that sometimes clears related complaints. Shut the cold supply, relieve pressure, clean the screen, restore supply.
4. Do not open the cabinet and start unplugging sensor plugs with power on, ohm out live circuits, chip scale off a probe with a screwdriver, or bypass the code to force hot water. Thermistor work is pro work. Guessing which white-white pair is which is how boards get damaged.
Gas appliances aren't where you get curious. A reset and a filter clean are fine. Sensor resistance tests and replacements are for someone who has the Rinnai chart and a meter.
When to call a pro
Call if Code 32 returns after a reset, if hot water temps are swinging or stuck wrong, if you also see scale-related codes (like LC) showing up in history, if someone already "cleaned something" inside the cabinet and the code came back, or if you need the unit restored safely before a busy weekday morning.
A proper service visit follows Rinnai's path: harness inspection, resistance check against the temperature chart, clean scale from the probe when it's salvageable, then sensor replacement when it's not. Around Charleston, Daniel Island, Mount Pleasant, and the rest of East Cooper, a lot of Code 32 calls start with scale or a tired harness — and some end with a thermistor that's simply worn out.
Soft next step
If your Rinnai is throwing Code 32 and you'd rather not guess — Avery & Sons Plumbing + Tankless can check the outlet sensor, clear scale if that's the issue, and get the reading back where the board expects it. Call (843) 305-5555 or visit averysplumbing.com. We're local, we work these units every week, and we'll tell you what it needs.
Don't ignore an outgoing temperature sensor fault — Code 32 is the unit saying it can't trust the water leaving the heater.



Comments